Place of use
These cables are used for connections in data communications . Designed for digital and analog signal carriages, these cables support 155 mbit/s systems.
Inner Conductor | Electrolytic Solid Annealed Copper Wire, |
Insulation | Solid PE EN50290-2-23, VDE 0207-2/2YI1 |
Core Identification | 1.Pair : Blue / Blue - White |
Stranding | Four Twisted Pairs Stranded |
Outer Sheath | PVC Compound, EN 50290-2-22, RAL 7032 Grey |
Product Code | Dimension and Weights | Electrical Properties | |||||||||
Nominal Cross Section | Overall Diemeter ( ~ ) |
Net Weight ( ~ ) |
Standart Lenght | Max. Dc Conductor Resistance at 20◦ C | Current Carrying Capacity | ||||||
In Ground at 20° C | On Air at 30° C |
CONDUCTOR RESISTANCE | INSULATION RESISTANCE | RESISTANCE UNBALANCED | OPERATING VOLTAGE (25ºC) | TEST VOLTAGE CORE/CORE | BEDING RADIUS | CHARACTERISTIC IMPEDANCE | TEMPERATURE RANGE | FLAME RETARDANT TEST | MUTUAL CAPACITANCE (1 KHz) | VELOCITY OF PROPAGATION |
Ω/km 94 | MΩ Km 5000 | %3 | V 250 | V 1200 | 8x D | Ω 100+15 | -20ºC+60ºC | IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 | pF/m 52 | %67 |
CORE IDENTIFICATION | COLOUR NUMBER | A WIRE | B WIRE |
1 | Blue | White/Blue | |
2 | Orange | White/Orange | |
3 | Green | White/Green | |
4 | Brown | White/Brown |